Technical Specifications
Dimensions: 191 × 70 × 31 mm
Material: ABS
Application: electrical work
Operating temperature range: 0–40 °C
Storage temperature: −10–+50 °C
Power supply: battery
Battery type: 2 × 1,5 V, AAA
Weight: 0,19 kg
Display type: LCD
Data hold: yes
Continuity test: 0–120 Ω
Conductivity test: yes
LED backlight: yes
Front light: yes
AC voltage: 0–600 V a.c.
DC voltage: 0–600 V d.c.
Resistance: 0–60 MΩ
Diode test: yes
Battery test: yes
AC current: 0–600 A
Capacitance: 0–20 mF
Frequency: 0–60 MHz
Sampling rate: 2,5–3 times per second
TRUE RMS: yes
Automatic measuring range selection: yes
Maximum opening of the measuring clamp: 26 mm
Maximum diameter of cable measured with the clamp: 18 mm
Audible signal: yes
Display reading range: 5999
Automatic shut-off: 15 min
Non-contact AC voltage detection NCV: yes
Low-pass filter VFC: yes
The YATO clamp multimeter YT-73092 is designed for basic and more advanced measurements of electrical circuits, and can measure alternating current up to 600 A.
For most measurements, the device selects the measuring range automatically.
The clamp measures current in a single wire using the induction method, without the need to interrupt the circuit or disconnect it from the power supply.
This makes it possible to measure higher current than with conventional electrical measuring instruments.
Measurements and tests
The device can measure AC and DC voltage as well as resistance. TRUE RMS, V.F.C. and LowZ functions can be used when measuring AC voltage; LowZ mode is available when measuring DC voltage. It can also perform a diode test (IF 1 mA, UR 2,3 V) and check circuit continuity. The diode test and continuity test can be switched on separately. During the continuity test, the device emits an audible signal when resistance is below 60 Ω. The NCV function detects AC voltage without contact.
Measurement accuracy
Example of AC current measurement: for a reading of 30 A, the accuracy in this range is ±(2,5% + 10) and the measurement resolution is 0,01 A.
The calculation is (30 × 2,5%) + (10 × 0,01 A) = 0,85 A, so the measurement result is 30 ± 0,85 A.
For an AC voltage reading of 235 V, the example error is ±3,3 V, and for a DC voltage reading of 12 V, it is ±0,116 V.
The table of measurement range resolution and accuracy is in the user manual.
TRUE RMS, NCV, LowZ and V.F.C.
TRUE RMS displays the true effective value of AC voltage or current.
Unlike devices that measure the average value, it gives an accurate result for sine waves as well as distorted sine, square or triangular signals.
This function is necessary, among other things, in circuits with switched-mode power supplies, motors with frequency converters and HVAC systems.
NCV detects AC voltage using the induction method, without contact with the wire.
This makes it possible to detect voltage in an insulated wire and identify the live wire.
LowZ mode allows AC and DC voltage to be measured with low impedance.
A disconnected wire may have so-called phantom voltage induced in it by a live wire in the same channel, making electrical network diagnostics more difficult.
Compared with the standard mode, LowZ reduces the impedance of the measuring instrument's inputs tenfold.
In this mode, the device draws slightly more current and helps dissipate the charge accumulated in the wire, so that phantom voltage does not affect the measurement result.
V.F.C. is a low-pass filter suitable, for example, for measuring the output of a drive that changes frequency and voltage to control an electric motor's speed.
When switched on, it filters out high-frequency interference, such as interference from a PWM signal, while allowing lower frequencies through.
This makes it possible to measure the effective value of the voltage or current supplied to the motor.
Automatic measuring range and HOLD
The AUTO function selects the measuring range automatically.
When measuring an unknown value manually, start with a higher range and work down to a smaller, more precise range; selecting the wrong range may damage the measuring instrument.
With automatic selection, a single measurement is enough for the device to find the appropriate range.
By default, the measuring instrument starts in AUTO SEL mode, which allows you to select the measurement mode, such as AC or DC voltage measurement, diode test, continuity test or resistance measurement.
HOLD retains the value currently measured on the display.
Display and construction
The LCD displays results up to a reading of 5999.
The display is backlit, and the measuring area of the clamp is also illuminated.
The device has overload protection, a low battery indicator and automatic shut-off after 15 minutes of inactivity.
The set includes test leads and a pouch.
Attention! To measure current, the clamp must be placed around a single core, i.e. one wire only. If the clamp is placed around a multi-core cable without isolating a single core, the result may be incorrect or show no current.
Dimensions: 191 × 70 × 31 mm
Material: ABS
Application: electrical work
Operating temperature range: 0–40 °C
Storage temperature: −10–+50 °C
Power supply: battery
Battery type: 2 × 1,5 V, AAA
Weight: 0,19 kg
Display type: LCD
Data hold: yes
Continuity test: 0–120 Ω
Conductivity test: yes
LED backlight: yes
Front light: yes
AC voltage: 0–600 V a.c.
DC voltage: 0–600 V d.c.
Resistance: 0–60 MΩ
Diode test: yes
Battery test: yes
AC current: 0–600 A
Capacitance: 0–20 mF
Frequency: 0–60 MHz
Sampling rate: 2,5–3 times per second
TRUE RMS: yes
Automatic measuring range selection: yes
Maximum opening of the measuring clamp: 26 mm
Maximum diameter of cable measured with the clamp: 18 mm
Audible signal: yes
Display reading range: 5999
Automatic shut-off: 15 min
Non-contact AC voltage detection NCV: yes
Low-pass filter VFC: yes
Returns & Warranty
Product returns
14-day right of withdrawal. Terms for consumers and business customers.
Return instructionsWarranty
All products come with manufacturer warranty as required by law.






Delivery time depends on stock
This product has no reviews yet. Be the first to rate it.
Product description
The YATO clamp multimeter YT-73092 is designed for basic and more advanced measurements of electrical circuits, and can measure alternating current up to 600 A.
For most measurements, the device selects the measuring range automatically.
The clamp measures current in a single wire using the induction method, without the need to interrupt the circuit or disconnect it from the power supply.
This makes it possible to measure higher current than with conventional electrical measuring instruments.
Measurements and tests
The device can measure AC and DC voltage as well as resistance. TRUE RMS, V.F.C. and LowZ functions can be used when measuring AC voltage; LowZ mode is available when measuring DC voltage. It can also perform a diode test (IF 1 mA, UR 2,3 V) and check circuit continuity. The diode test and continuity test can be switched on separately. During the continuity test, the device emits an audible signal when resistance is below 60 Ω. The NCV function detects AC voltage without contact.
Measurement accuracy
Example of AC current measurement: for a reading of 30 A, the accuracy in this range is ±(2,5% + 10) and the measurement resolution is 0,01 A.
The calculation is (30 × 2,5%) + (10 × 0,01 A) = 0,85 A, so the measurement result is 30 ± 0,85 A.
For an AC voltage reading of 235 V, the example error is ±3,3 V, and for a DC voltage reading of 12 V, it is ±0,116 V.
The table of measurement range resolution and accuracy is in the user manual.
TRUE RMS, NCV, LowZ and V.F.C.
TRUE RMS displays the true effective value of AC voltage or current.
Unlike devices that measure the average value, it gives an accurate result for sine waves as well as distorted sine, square or triangular signals.
This function is necessary, among other things, in circuits with switched-mode power supplies, motors with frequency converters and HVAC systems.
NCV detects AC voltage using the induction method, without contact with the wire.
This makes it possible to detect voltage in an insulated wire and identify the live wire.
LowZ mode allows AC and DC voltage to be measured with low impedance.
A disconnected wire may have so-called phantom voltage induced in it by a live wire in the same channel, making electrical network diagnostics more difficult.
Compared with the standard mode, LowZ reduces the impedance of the measuring instrument's inputs tenfold.
In this mode, the device draws slightly more current and helps dissipate the charge accumulated in the wire, so that phantom voltage does not affect the measurement result.
V.F.C. is a low-pass filter suitable, for example, for measuring the output of a drive that changes frequency and voltage to control an electric motor's speed.
When switched on, it filters out high-frequency interference, such as interference from a PWM signal, while allowing lower frequencies through.
This makes it possible to measure the effective value of the voltage or current supplied to the motor.
Automatic measuring range and HOLD
The AUTO function selects the measuring range automatically.
When measuring an unknown value manually, start with a higher range and work down to a smaller, more precise range; selecting the wrong range may damage the measuring instrument.
With automatic selection, a single measurement is enough for the device to find the appropriate range.
By default, the measuring instrument starts in AUTO SEL mode, which allows you to select the measurement mode, such as AC or DC voltage measurement, diode test, continuity test or resistance measurement.
HOLD retains the value currently measured on the display.
Display and construction
The LCD displays results up to a reading of 5999.
The display is backlit, and the measuring area of the clamp is also illuminated.
The device has overload protection, a low battery indicator and automatic shut-off after 15 minutes of inactivity.
The set includes test leads and a pouch.
Attention! To measure current, the clamp must be placed around a single core, i.e. one wire only. If the clamp is placed around a multi-core cable without isolating a single core, the result may be incorrect or show no current.
Shipping & Delivery






Delivery time depends on stock
Returns & Warranty
Product returns
14-day right of withdrawal. Terms for consumers and business customers.
Return instructionsWarranty
All products come with manufacturer warranty as required by law.
Reviews
This product has no reviews yet. Be the first to rate it.

YATO clamp multimeter 0–600 A, 0–600 V
YT-73092